fbpx
Model Possibility to connect wireless detectors Cellular communication technology Has an integrated SIM card (eSIM)  Slot for the user’s SIM card Cellular service plan Cloud services1
S16cmR    2G       Yes   1 year2
S16emR   2G LTE-M     Yes   1 year2
S16gmR   2G   LTE CAT1   Yes   1 year2
S16cm Yes 2G       Yes   1 year2
S16em Yes 2G LTE-M     Yes   1 year2
S16gm Yes 2G   LTE CAT1   Yes   1 year2
S16cJ Yes 2G     Yes Yes 2 years3 Yes3
S16eT Yes 2G LTE-M   Yes Yes 2 years3 Yes3
S16eJ Yes 2G LTE-M   Yes Yes 2 years3 Yes3
S16gT Yes 2G   LTE CAT1 Yes Yes 2 years3 Yes3
S16gJ Yes 2G   LTE CAT1 Yes Yes 2 years3 Yes3
S16cER   2G     Yes   10 years4 2 years4
S16eER   2G LTE-M    Yes   10 years4 2 years4
S16gER, S16gAR   2G   LTE CAT1 Yes   10 years4 2 years4
S16cE Yes 2G     Yes   10 years4 2 years4
S16eE Yes 2G LTE-M   Yes   10 years4 2 years4
S16gE, S16gA Yes 2G   LTE CAT1 Yes   10 years4 2 years4

   1 - Control via the internet using a cloud is a paid service. It can be activated or extended by purchasing a voucher and activating it in your

ALARMSERVER.NET account.

   2 - To activate or extend the service, the user must purchase a WLCT voucher and activate it in their ALARMSERVER.NET account. The voucher can be

purchased at: shop.secolink.eu.

   3 - The service period starts when the system connects to the mobile network, and its duration is counted from that moment. Once the paid period ends,

the user will be offered the option to extend the mobile service. The service is extended by purchasing a GSIM voucher. Throughout the entire mobile service period, the control via the cloud will be free of charge. If the service is not extended, the user can insert their own SIM card and, after configuring the control panel accordingly, continue using it—for example, by controlling it via SMS commands. Alternatively, they can purchase and activate a separate WLCT voucher for control via internet. Before purchasing the control panel, it is recommended to check whether the cost of the extension (GSIM voucher) is acceptable. The voucher can be purchased at: shop.secolink.eu.

   4 - The mobile service for the product remains active only as long as the SECOLINK PRO app is installed on the user's phone and the specified control panel

is added to it. Cloud-based control will be free for the first two years. After two years, if the user wishes to continue using cloud services, they must purchase a WLCT (or IPCT) voucher and activate it in their ALARMSERVER.NET account. The WLCT voucher can be purchased at shop.secolink.eu

  

Main features of the control panel
Alarm system concept Hybrid modular system
On-board wired zones 5/10 (doubling)
2-wire smoke detector input 1
On-board wireless zones 16
Maximum zones in system 16
On-board PGM 3
Maximum PGM in system 16
User + installer codes 31+1
Duress code Yes
Defaulting user code Yes
Key switch zone Yes
Partitions 4
"Shared" partition (common area) Yes
System timers 16
Maximum keypads/modules in system 5
Keypad compatibility All SECOLINK keypads
Event log buffer 256 (with keypad 512)
Interface with transmitters and communicators of other manufacturers -
Data bus protocol KRBUS 
"Roller" detector type Yes
"Vibration" detector type Yes
"Vibration" zone speed (sensitivity) 0.01 - 0.25 sec.
Normal zone speed (sensitivity) 0.1 - 2.5 sec.
Zone loop (detector) type NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration, Roller, Wireless
Arming mode Away, Max Away, Night, Stay.
Zone definitions Entry/exit, entry/exit forced, interior, interior night armed, follower, follower night armed, perimeter, instant, PGM control;
24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature
Zone attributes Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night
PGM definitions Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch
PGM attributes Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification, armed in specific mode
Remote system control and notification to user via internet
Number of recipients for internet messaging using app SECOLINK PRO  10
Requirements for system control via internet using the SECOLINK PRO app
  • the system user must create an account in the ALARMSERVER.NET cloud and register the product by entering the product identification number "BI";
  • the online service must be activated for the system;
Push notifications Yes
Notifications to the user using user's SIM card (SMS, call)
SIM slot size Micro SIM
Number of recipients for SMS, voice clip messaging  5
Alarm message for end user by voice clip Only S16gmR, S16gm
Voice guide for end user Only S16gmR, S16gm
SMS out (device >> phone) Yes
SMS in (phone >> device) Yes
SMS text language (device >> phone) Can be changed using MASCAD PRO
Operation of SECOLINK PRO using SMS services  plain text1
Reporting to Central Monitoring Station (CMS)
Reporting to CMS Yes
Reporting to CMS format CID by GPRS/LTE-M/LTE CAT1
Reporting protocols for CMS E2 (Enigma), FIBRO (Sur-gard), CSV (Patriot), SIA
Compatible with SG-SYSTEM II , III IP card Yes
Maximum load and electrical characteristics
Rated voltage of power supply (AC) ~20 V

Minimum AC voltage

(note: ~16 V input voltage lets control panel to generate max 0,5 A output current)

~16 V 

Maximum AC voltage

(Note: higher than ~22 V voltage can damage control panel)

~22
Maximum long term output current of control panel (I+AUX + I+BELL + IBATTERY CHARGE ≤0,7 A
Maximum current of slow blowing fuse used in primary AC 250 mA 
Maximum AC power consumption 150 mA
Minimum voltage on +AUX, +BELL outputs 12 V 
Maximum voltage on +AUX, +BELL outputs 13,9 V 
Maximum current out of +AUX +0,5 A
Maximum current out of +BELL +2 A
Maximum current into -PGM1 -0,15 A
Maximum current into -PGM2 -0,15 A
Short circuit, overload protection of +BELL, +AUX Electronic
Battery charge, +BELL, +AUX current measurement Yes
Failed (waste) backup battery disconnection Yes
Maximum battery charging current +0,2 A
Maximum current of fast blowing fuse used in battery circuit 2,5 A
Control panel disconnect battery when it’s voltage less than 9,5 V
Operational compliance EN50131, Grade2 
Recommended backup battery 12 V, 2,2 - 7Ah
Overall dimensions W x H in mm 145 x 77
Environmental compliance ROHS 
Operating temperature From -10oC up to +50o
Remote programming of control panel settings Yes
Production status In production
Interface with PC USB micro-B 
Latest firmware version Download
Wiring manual Download
Programming manual (for keypad KM20Bx) Download
Programming manual (for keypads KM24x, KM25) Download
 

   1 - SMS messages from the control panel are not imported into the SECOLINK PRO app - they can be viewed using the SMS editing app on the phone. Lock

icons (ARMED / DISARMED) are not displayed in the app. SMS commands are not performed in the background - SECOLINK PRO will „insert“ the control command for the user into SMS editing app and the user will need to tap on the button Send.