Model Maximum zones in system Possibility to connect wireless detectors On-board wireless zones Maximum keypads/modules in system
L16R 16     3
L32R 32     5
L16 16 Yes  16 3
L32 32 Yes  32 5

 

 

Main features of the control panel
Alarm system concept Hybrid modular system
On-board wired zones 5/10 (doubling)
2-wire smoke detector input 1
On-board PGM 3
Maximum PGM in system 16
User + installer codes 31+1
Duress code Yes
Defaulting user code Yes
Key switch zone Yes
Partitions 4
"Shared" partition (common area) Yes
System timers 16
Keypad compatibility All SECOLINK keypads
Event log buffer 256 (with keypad 512)
Interface with transmitters and communicators of other manufacturers -
Data bus protocol KRBUS 
"Roller" detector type Yes
"Vibration" detector type Yes
"Vibration" zone speed (sensitivity) 0.01 - 0.25 sec.
Normal zone speed (sensitivity) 0.1 - 2.5 sec.
Zone loop (detector) type NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration, Roller, Wireless
Arming mode Away, Max Away, Night, Stay.
Zone definitions

Entry/exit, entry/exit forced, interior, interior night armed, follower, follower night armed, perimeter, instant, PGM control;


24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature

Zone attributes Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night
PGM definitions Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch
PGM attributes Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification, armed in specific mode
Additional services
Additional services that are included in the final price of the product
  • the control panels comes with 2 years of paid cloud services1, allowing the user to take full advantage of the SECOLINK PRO app.

 

Note: the service for the product will be activated when the user registers the product in their ALARMSERVER.NET account by entering the purchased product's identification number "BI" and adding the product to their SECOLINK PRO app.

Remote system control and notification to user via internet
Number of recipients for internet messaging using app SECOLINK PRO  10
Requirements for system control via internet using the SECOLINK PRO app
  • the system user must create an account in the ALARMSERVER.NET cloud and register the product by entering the product identification number "BI";
Push notifications Yes
Reporting to Central Monitoring Station (CMS)
Reporting to CMS Yes
Reporting to CMS format CID by LAN / Wi-Fi
Reporting protocols for CMS E2 (Enigma), FIBRO (Sur-gard), CSV (Patriot), SIA
Compatible with SG-SYSTEM II , III IP card Yes
Maximum load and electrical characteristics
Rated voltage of power supply (AC) ~20 V

Minimum AC voltage

(note: ~16 V input voltage lets control panel to generate max 0,5 A output current)

~16 V 

Maximum AC voltage

(Note: higher than ~22 V voltage can damage control panel)

~22
Maximum long term output current of control panel (I+AUX + I+BELL + IBATTERY CHARGE ≤0,7 A
Maximum current of slow blowing fuse used in primary AC 250 mA 
Maximum AC power consumption 150 mA
Minimum voltage on +AUX, +BELL outputs 12 V 
Maximum voltage on +AUX, +BELL outputs 13,9 V 
Maximum current out of +AUX +0.5 A
Maximum current out of +BELL +2 A
Maximum current into -PGM1 -0.15 A
Maximum current into -PGM2 -0.15 A
Short circuit, overload protection of +BELL, +AUX Electronic
Battery charge, +BELL, +AUX current measurement Yes
Failed (waste) backup battery disconnection Yes
Maximum battery charging current +0.2 A
Maximum current of fast blowing fuse used in battery circuit 2.5 A
Control panel disconnect battery when it’s voltage less than 9.5 V
Operational compliance EN50131, Grade2 
Recommended backup battery 12 V, 2,2 - 7Ah
Overall dimensions W x H in mm 145 x 77
Environmental compliance ROHS 
Operating temperature From -10oC up to +50o
Remote programming of control panel settings Yes
Production status In production
Interface with PC USB micro-B 
Latest firmware version Download
Wiring manual Download
Programming manual (for keypad KM20Bx) Download
Programming manual (for keypads KM24x, KM25) Download
 

   1 - At the end of the paid period, the user will be offered to extend the service. The service is extended by purchasing a WLCT voucher. Without extending

the service, the system will only be able to report to the security service. Before purchasing the control panel, it is recommended to check if the price of the extension (WLCT voucher) is acceptable. The voucher can be purchased at shop.secolink.eu