Model | Maximum zones in system | Possibility to connect wireless detectors | On-board wireless zones | Maximum keypads/modules in system |
L16R | 16 | 3 | ||
L32R | 32 | 5 | ||
L16 | 16 | Yes | 16 | 3 |
L32 | 32 | Yes | 32 | 5 |
Main features of the control panel | |
Alarm system concept | Hybrid modular system |
On-board wired zones | 5/10 (doubling) |
2-wire smoke detector input | 1 |
On-board PGM | 3 |
Maximum PGM in system | 16 |
User + installer codes | 31+1 |
Duress code | Yes |
Defaulting user code | Yes |
Key switch zone | Yes |
Partitions | 4 |
"Shared" partition (common area) | Yes |
System timers | 16 |
Keypad compatibility | All SECOLINK keypads |
Event log buffer | 256 (with keypad 512) |
Interface with transmitters and communicators of other manufacturers | - |
Data bus protocol | KRBUS |
"Roller" detector type | Yes |
"Vibration" detector type | Yes |
"Vibration" zone speed (sensitivity) | 0.01 - 0.25 sec. |
Normal zone speed (sensitivity) | 0.1 - 2.5 sec. |
Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration, Roller, Wireless |
Arming mode | Away, Max Away, Night, Stay. |
Zone definitions | Entry/exit, entry/exit forced, interior, interior night armed, follower, follower night armed, perimeter, instant, PGM control;
|
Zone attributes | Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night |
PGM definitions | Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch |
PGM attributes | Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification, armed in specific mode |
Additional services | |
Additional services that are included in the final price of the product |
Note: the service for the product will be activated when the user registers the product in their ALARMSERVER.NET account by entering the purchased product's identification number "BI" and adding the product to their SECOLINK PRO app. |
Remote system control and notification to user via internet | |
Number of recipients for internet messaging using app SECOLINK PRO | 10 |
Requirements for system control via internet using the SECOLINK PRO app |
|
Push notifications | Yes |
Reporting to Central Monitoring Station (CMS) | |
Reporting to CMS | Yes |
Reporting to CMS format | CID by LAN / Wi-Fi |
Reporting protocols for CMS | E2 (Enigma), FIBRO (Sur-gard), CSV (Patriot), SIA |
Compatible with SG-SYSTEM II , III IP card | Yes |
Maximum load and electrical characteristics | |
Rated voltage of power supply (AC) | ~20 V |
Minimum AC voltage (note: ~16 V input voltage lets control panel to generate max 0,5 A output current) | ~16 V |
Maximum AC voltage (Note: higher than ~22 V voltage can damage control panel) | ~22 |
Maximum long term output current of control panel (I+AUX + I+BELL + IBATTERY CHARGE) | ≤0,7 A |
Maximum current of slow blowing fuse used in primary AC | 250 mA |
Maximum AC power consumption | 150 mA |
Minimum voltage on +AUX, +BELL outputs | 12 V |
Maximum voltage on +AUX, +BELL outputs | 13,9 V |
Maximum current out of +AUX | +0.5 A |
Maximum current out of +BELL | +2 A |
Maximum current into -PGM1 | -0.15 A |
Maximum current into -PGM2 | -0.15 A |
Short circuit, overload protection of +BELL, +AUX | Electronic |
Battery charge, +BELL, +AUX current measurement | Yes |
Failed (waste) backup battery disconnection | Yes |
Maximum battery charging current | +0.2 A |
Maximum current of fast blowing fuse used in battery circuit | 2.5 A |
Control panel disconnect battery when it’s voltage less than | 9.5 V |
Operational compliance | EN50131, Grade2 |
Recommended backup battery | 12 V, 2,2 - 7Ah |
Overall dimensions W x H in mm | 145 x 77 |
Environmental compliance | ROHS |
Operating temperature | From -10oC up to +50oC |
Remote programming of control panel settings | Yes |
Production status | In production |
Interface with PC | USB micro-B |
Latest firmware version | ![]() |
Wiring manual | ![]() |
Programming manual (for keypad KM20Bx) | ![]() |
Programming manual (for keypads KM24x, KM25) | ![]() |
1 - At the end of the paid period, the user will be offered to extend the service. The service is extended by purchasing a WLCT voucher. Without extending the service, the system will only be able to report to the security service. Before purchasing the control panel, it is recommended to check if the price of the extension (WLCT voucher) is acceptable. The voucher can be purchased at shop.secolink.eu |