Features | P16 | P32 | P64 |
Alarm system concept | Hybrid modular system | Hybrid modular system | Hybrid modular system |
On-board wired zones | 7/14 (doubling) | 7/14 (doubling) | 7/14 (doubling) |
2-wire smoke detector input | 1 | 1 | 1 |
On-board wireless zones | 16 | 32 | 64 |
Maximum zones in system | 16 | 32 | 64 |
On-board PGM | 3 | 3 | 3 |
Maximum PGM in system | 16 | 16 | 16 |
User + installer codes | 31+1 | 31+1 | 63+1 |
Duress code | X1, X2, X3, X4 (when X4 = X4 + 1) | ||
Defaulting user code | Yes | Yes | Yes |
Key switch zone | Yes | Yes | Yes |
Partitions | 4 | 4 | 4 |
"Shared" partition (common area) | Yes | Yes | Yes |
System timers | 16 | 16 | 16 |
Maximum keypads/modules in system | 15 | 15 | 15 |
Keypad compatibility | All SECOLINK keypads | All SECOLINK keypads | Only KM24G, KM25 |
Event log buffer | 512 | 512 | 512 |
PSTN communicator | Plug-on | Plug-on | Plug-on |
In-built interface for backup communicator | TTL Serial | TTL Serial | TTL Serial |
Data bus protocol | KRBUS | KRBUS | KRBUS |
Total phone numbers: CMS reporting + personal dialing | 9 | 9 | 9 |
Maximum phone numbers for personal dialing | Up to 5 | Up to 5 | Up to 5 |
Maximum phone numbers for CMS reporting | Up to 4 | Up to 4 | Up to 4 |
Reporting protocol | Contact ID | Contact ID | Contact ID |
Voice guide for system control over PSTN | Yes | Yes | Yes |
Voice guide for system programming over PSTN | Yes | Yes | Yes |
"Roller" detector type | Yes | Yes | Yes |
"Vibration" detector type | Yes | Yes | Yes |
"Vibration" zone speed (sensitivity) | 0.01 - 0.25 sec. | 0.01 - 0.25 sec. | 0.01 - 0.25 sec. |
Normal zone speed (sensitivity) | 0.1 - 2.5 sec. | 0.1 - 2.5 sec. | 0.1 - 2.5 sec. |
Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration, Roller | ||
Arming mode | Away, Max Away, Night, Stay. | ||
Zone definition | Entry/exit, entry/exit forced, interior, interior night armed, follower, follower night armed, perimeter, instant, PGM control; 24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature | ||
Zone attributes | Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night | ||
PGM definition | Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch | ||
PGM attributes | Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification, armed in specific mode | ||
Rated voltage of power supply (AC) | ~20 V | ~20 V | ~20 V |
Minimum AC voltage (note: ~16 V input voltage lets control panel to generate max 0.7 A output current) | ~16 V | ~16 V | ~16 V |
Maximum AC voltage (Note: higher than ~22 V voltage can damage control panel) | ~22 V | ~22 V | ~22 V |
Maximum long term output current of control panel (I+AUX + I+BELL + I+PGM + battery charge): | ≤1.5 A | ≤2.0 A | ≤2.0 A |
Maximum current of slow blowing fuse used in primary AC | 250 mA | 250 mA | 250 mA |
Maximum AC power consumption | 150 mA | 150 mA | 150 mA |
Minimum voltage on +AUX, +BELL, +PGM outputs | 12 V | 12 V | 12 V |
Maximum voltage on +AUX, +BELL, +PGM outputs | 13.9 V | 13.9 V | 13.9 V |
Maximum current out of +AUX | +1 A | +1 A | +1 A |
Maximum current out of +BELL | +2 A | +2 A | +2 A |
Maximum current into -PGM | -0.3 A | -0.3 A | -0.3 A |
Maximum current out of +PGM | +0.5 A | +0.9 A | +0.9 A |
Short circuit, overload protection of +BELL, +PGM, +AUX | Electronic | Electronic | Electronic |
Battery charge, +BELL, +AUX current measurement | Yes | Yes | Yes |
Failed (waste) backup battery disconnection | Yes | Yes | Yes |
Maximum battery charging current | 0.35 A | 0.35 A | 0.35 A |
Maximum current of fast blowing fuse used in battery circuit | 3.15 A | 3.15 A | 3.15 A |
Control panel disconnect battery when it’s voltage less than | 9.5 V | 9.5 V | 9.5 V |
Recommended backup battery | 12 V, 7 Ah / 20 Hr | 12 V, 7 Ah / 20 Hr | 12 V, 7 Ah / 20 Hr |
Operational compliance | EN50131, Grade2 | EN50131, Grade2 | EN50131, Grade2 |
Overall dimensions W x H in mm | 145 x 77 | 145 x 77 | 145 x 77 |
Environmental compliance | ROHS | ROHS | ROHS |
Operating temperature | -10oC up to +50oC | ||
Production status | In production | In production | In production |
Interface with PC | USB mini-B | USB mini-B | USB mini-B |
Latest firmware version | Download | ||
Wiring manual | Download | ||
Programming manual (for KM20B keypad) | Download | ||
Programming manual (for KM24x, KM25 keypads) | Download |