Model | Possibility to connect wireless detectors | Cellular communication technology | Has an integrated SIM card (eSIM) | Cellular service plan | Cloud services1 | ||
S32emR | 2G | LTE-M | 1 year2 | ||||
S32gmR | 2G | LTE CAT1 | 1 year2 | ||||
S32em | Yes | 2G | LTE-M | 1 year2 | |||
S32gm | Yes | 2G | LTE CAT1 | 1 year2 | |||
S32eT | Yes | 2G | LTE-M | Yes | 2 years3 | Yes3 | |
S32eJ | Yes | 2G | LTE-M | Yes | 2 years3 | Yes3 | |
S32gT | Yes | 2G | LTE CAT1 | Yes | 2 years3 | Yes3 | |
S32gJ | Yes | 2G | LTE CAT1 | Yes | 2 years3 | Yes3 | |
S32cER | 2G | Yes | 10 years4 | 2 years4 | |||
S32cE | Yes | 2G | Yes | 10 years4 | 2 years4 | ||
S32eE | Yes | 2G | LTE-M | Yes | 10 years4 | 2 years4 | |
S32gE | Yes | 2G | LTE CAT1 | Yes | 10 years4 | 2 years4 | |
S32gA | Yes | 2G | LTE CAT1 | Yes | 10 years4 | 2 years4 | |
1 - Control via the internet using a cloud is a paid service. It can be activated or extended by purchasing a voucher and activating it in your ALARMSERVER.NET account. 2 - To activate or extend the service, the user must purchase a WLCT voucher and activate it in their ALARMSERVER.NET account. The voucher can be purchased at: shop.secolink.eu. 3 - The service period starts when the system connects to the mobile network, and its duration is counted from that moment. Once the paid period ends, the user will be offered the option to extend the mobile service. The service is extended by purchasing a GSIM voucher. Throughout the entire mobile service period, the control via the cloud will be free of charge. If the service is not extended, the user can insert their own SIM card and, after configuring the control panel accordingly, continue using it—for example, by controlling it via SMS commands. Alternatively, they can purchase and activate a separate WLCT voucher for control via internet. Before purchasing the control panel, it is recommended to check whether the cost of the extension (GSIM voucher) is acceptable. The voucher can be purchased at: shop.secolink.eu. 4 - The mobile service for the product remains active only as long as the SECOLINK PRO app is installed on the user's phone and the specified control panel is added to it. Cloud-based control will be free for the first two years. After two years, if the user wishes to continue using cloud services, they must purchase a WLCT (or IPCT) voucher and activate it in their ALARMSERVER.NET account. The WLCT voucher can be purchased at shop.secolink.eu. |
Main features of the control panel | |
Alarm system concept | Hybrid modular system |
On-board wired zones | 5/10 (doubling) |
2-wire smoke detector input | 1 |
On-board wireless zones | 32 |
Maximum zones in system | 32 |
On-board PGM | 3 |
Maximum PGM in system | 16 |
User + installer codes | 31+1 |
Duress code | Yes |
Defaulting user code | Yes |
Key switch zone | Yes |
Partitions | 4 |
"Shared" partition (common area) | Yes |
System timers | 16 |
Maximum keypads/modules in system | 5 |
Keypad compatibility | All SECOLINK keypads |
Event log buffer | 256 (with keypad 512) |
Interface with transmitters and communicators of other manufacturers | - |
Data bus protocol | KRBUS |
"Roller" detector type | Yes |
"Vibration" detector type | Yes |
"Vibration" zone speed (sensitivity) | 0.01 - 0.25 sec. |
Normal zone speed (sensitivity) | 0.1 - 2.5 sec. |
Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration, Roller, Wireless |
Arming mode | Away, Max Away, Night, Stay. |
Zone definitions | Entry/exit, entry/exit forced, interior, interior night armed, follower, follower night armed, perimeter, instant, PGM control; 24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature |
Zone attributes | Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night |
PGM definitions | Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch |
PGM attributes | Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification, armed in specific mode |
Remote system control and notification to user via internet | |
Number of recipients for internet messaging using app SECOLINK PRO | 10 |
Requirements for system control via internet using the SECOLINK PRO app |
|
Push notifications | Yes |
Notifications to the user using user's SIM card (SMS, call) | |
User SIM | Yes (size: micro SIM) |
Number of recipients for SMS, voice clip messaging | 5 |
Alarm message for end user by voice clip | Only S32gmR, S32gm |
Voice guide for end user | Only S32gmR, S32gm |
SMS out (device >> phone) | Yes |
SMS in (phone >> device) | Yes |
SMS text language (device >> phone) | Can be changed using MASCAD PRO |
Operation of SECOLINK PRO using SMS services: | |
Android | plain text1 |
iPhone | plain text1 |
Reporting to Central Monitoring Station (CMS) | |
Reporting to CMS | Yes |
Reporting to CMS format | CID by GPRS/LTE-M/LTE CAT1 |
Reporting protocols for CMS | E2 (Enigma), FIBRO (Sur-gard), CSV (Patriot), SIA |
Compatible with SG-SYSTEM II , III IP card | Yes |
Maximum load and electrical characteristics | |
Rated voltage of power supply (AC) | ~20 V |
Minimum AC voltage (note: ~16 V input voltage lets control panel to generate max 0,5 A output current) | ~16 V |
Maximum AC voltage (Note: higher than ~22 V voltage can damage control panel) | ~22 |
Requirements for a AC power transformer | Attention: S32 series control panels are intended for installation in a CAS6 plastic casing. These control panels cannot be installed in the CAS4 plastic casing due to the low power AC transformer used in it. |
Maximum long term output current of control panel (I+AUX + I+BELL + IBATTERY CHARGE) | ≤1 A |
Maximum current of slow blowing fuse used in primary AC | 250 mA |
Maximum AC power consumption | 150 mA |
Minimum voltage on +AUX, +BELL outputs | 12 V |
Maximum voltage on +AUX, +BELL outputs | 13,9 V |
Maximum current out of +AUX | +0,8 A |
Maximum current out of +BELL | +2 A |
Maximum current into -PGM1 | -0,15 A |
Maximum current into -PGM2 | -0,15 A |
Short circuit, overload protection of +BELL, +AUX | Electronic |
Battery charge, +BELL, +AUX current measurement | Yes |
Failed (waste) backup battery disconnection | Yes |
Maximum battery charging current | +0,2 A |
Maximum current of fast blowing fuse used in battery circuit | 2,5 A |
Control panel disconnect battery when it’s voltage less than | 9,5 V |
Operational compliance | EN50131, Grade2 |
Recommended backup battery | 12 V, 2,2 - 7Ah |
Overall dimensions W x H in mm | 145 x 77 |
Environmental compliance | ROHS |
Operating temperature | From -10oC up to +50oC |
Remote programming of control panel settings | Yes |
Production status | In production |
Interface with PC | USB micro-B |
Latest firmware version | ![]() |
Wiring manual | ![]() |
Programming manual (for keypad KM20Bx) | ![]() |
Programming manual (for keypads KM24x, KM25) | ![]() |
1 - SMS messages from the control panel are not imported into the SECOLINK PRO app - they can be viewed using the SMS editing app on the phone. Lock icons (ARMED / DISARMED) are not displayed in the app. SMS commands are not performed in the background - SECOLINK PRO will „insert“ the control command for the user into SMS editing app and the user will need to tap on the button Send. |